Solenoid Valve, Number of Ways 2, Configuration Normally Closed, Cv Flow Factor 0.22, 1/8 Pipe Size (In.), 3/32 Orifice Dia. (In.), PSI Differential Min. 0, Safe Working Water PSI 500, 34.0 Airflow (SCFM), 180 Max. Fluid Temp. (F), Coil Insulation Class F, Coil Enclosure NEMA 1X, Body Material Brass, Gasket Material Buna N, Construction Reference 1, Length 13/16 In., Width 13/16 In., Height 23/4 In.
Restrictions- WARNING: Not for use in explosive atmospheres. Note: Maximum suggested cycling rate is 10 times per min.
- California Proposition 65 Warning: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.
Solenoid Valves- To prevent backflow, add a check valve to the system (sold separately on page 4414). Valves that have OPD minimums beginning with 0 (e.g., 0 to 300 psi) are direct-acting and will open and close when line pressures are within minimum and maximum psi ranges. Valves that have OPD minimums starting at 2 or 5 (e.g., 5 to 150 psi) are designated pilot-operated and will open and close only if pressure differential between the inlet and outlet is within OPD ranges. Normally closed valves will open when energized. Normally open valves will close when energized.
- Standards: UL; CSA; Fluid Control Institute, Inc.; National Fluid Power Association (NFPA).
- Mount in any position