Dayton 3A431

Dayton

Solenoid Valve, 2 Way, NC, 1/4 In, SS

3A431 160233
Average Rating: n/a
 Be the first to write a review!
$39.29 + 3 Business Day Shipping $7.15

Sponsored Links

Specs

ItemSolenoid Valve
Number of Ways2
ConfigurationNormally Closed
Cv Flow Factor0.48
Pipe Size (In.)1/4
Orifice Dia. (In.)5/32
PSI Differential Min.0
Max. PSI Differential Air/Water100
Safe Working Water PSI500
GPM Max.4.8
Min. Flow Rate (GPM)0.48
Airflow (SCFM)27.4
Coefficient of Volume0.48
Coil KeyA
Max. Fluid Temp. (F)180
Coil Insulation ClassF
Coil EnclosureNEMA Type 1
Body MaterialStainless Steel
Gasket MaterialBuna N
Construction Reference No.1
Length1-1/2"
Width1-1/2"
Center Line Pipe Center Size (In.)5/16
Height2-7/8"
Agency ComplianceCSA, NFPA, UL
UNSPSC40141605
Weight 0.650000

Description

Solenoid Valve, Number of Ways 2, Configuration Normally Closed, Cv Flow Factor 0.48, 1/4 Pipe Size (In.), 5/32 Orifice Dia. (In.), PSI Differential Min. 0, Safe Working Water PSI 500, 27.4 Airflow (SCFM), 180 Max. Fluid Temp. (F), Coil Insulation Class F, Coil Enclosure NEMA Type 1, Body Material Stainless Steel, Gasket Material Buna N, Construction Reference 1, Length 11/2 In., Width 11/2 In., Height 27/8 In.

Restrictions
  • WARNING: Not for use in explosive atmospheres. Note: Maximum suggested cycling rate is 10 times per min.

Solenoid Valves
  • To prevent backflow, add a check valve to the system (sold separately on page 4414). Valves that have OPD minimums beginning with 0 (e.g., 0 to 300 psi) are direct-acting and will open and close when line pressures are within minimum and maximum psi ranges. Valves that have OPD minimums starting at 2 or 5 (e.g., 5 to 150 psi) are designated pilot-operated and will open and close only if pressure differential between the inlet and outlet is within OPD ranges. Normally closed valves will open when energized. Normally open valves will close when energized.
  • Standards: UL; CSA; Fluid Control Institute, Inc.; National Fluid Power Association (NFPA).
  • Mount in any position

More Products
Maxitrol RV47L (1/2") Regulator, Gas PressureMaxitrolRegulator, Gas PressureRV47L (1/2")50063(0 reviews)$26.61 + $7.15 Shipping
Honeywell SV9501M2528 Valve, Natural GasHoneywellValve, Natural GasSV9501M2528686312(0 reviews)$198.94 + $9.55 Shipping
Honeywell VR8200A2132 Combination Dual Gas ValveHoneywellCombination Dual Gas ValveVR8200A2132686011(0 reviews)$77.89 + $11.90 Shipping
White Rodgers 1311-102 Hot Water Zone Control ValveWhite RodgersHot Water Zone Control Valve1311-10250162(0 reviews)$127.53 + $10.20 Shipping
Ingersoll-Rand/Aro P251SS-012-D Valve, Solenoid, 1/8 InIngersoll-Rand/AroValve, Solenoid, 1/8 InP251SS-012-D41795(0 reviews)$52.50 + $7.15 Shipping