Dayton 6KWJ2

Dayton

Exhaust Ventilator, 11 In, 115/208-230 V

6KWJ2 1617704
Average Rating: n/a
 Be the first to write a review!
$1,332.21 + 3 Business Day Shipping $52.00

Sponsored Links

Specs

ItemExhaust Ventilator
TypeHazardous Location, Centrifugal Sidewall Direct Drive
Wheel Dia. (In.)11
CFM @ 0.000-In. SP1180
CFM @ 0.125-In. SP1094
CFM @ 0.250-In. SP1017
CFM @ 0.375-In. SP929
CFM @ 0.500-In. SP824
CFM @ 0.625-In. SP712
CFM @ 0.750-In. SP586
Sones @ 0.125-In. SP @ 5 Ft.13.4
Sones @ 0.250-In. SP @ 5 Ft.13.0
Motor Voltage115/208-230
Phase1
Hz60
Max. Operating Amps4.0/2.0-2.0
Motor HP1/4
Max. BHP0.20
RPM1725
Base Width (In.)19 3/4 Dia
Base Length (In.)19 3/4 Dia
Base Height (In.)1-3/4
Overall Dia. (In.)24-3/8
Overall Height (In.)23-3/4
Shaft Dia. Wheel End (In.)1/2
Mounting LocationWall
Max. Inlet Temp. (Deg. F)300
Housing MaterialSpun Aluminum
Wheel MaterialAluminum
Wheel TypeBackward Incline
Speed ControllableNo
Agency ComplianceAMCA Sound & Air
Includes NEMA 7 & 9 Disconnect Switch, Mounted & Wired, Hazardous Location Motor That Meets Class I, Groups C & D and Class II, Groups F & G
Recommended Damper Size (In.)10 x 10
Recommended Damper Stock No.4HX73
Weight 70.000000
SKUs 6KWJ2

Description

Centrifugal Direct-Drive Upblast Exhaust VentilatorsAluminum, backward-inclined wheel 1-piece rolled aluminum windband fully welded to base Motor, drive frame, and blower wheel are isolated from mounting base Motor compartment is isolated from contaminated air NEMA 1 junction box in motor enclosure (Hazardous units have NEMA 7 & 9 disconnect switch) UL and C-UL Listed (Motor only UL Listed for Class I Groups C & D, and Class II Groups F & G for hazardous location units)Note: Speed controllers available for 115V units only. For kitchen application, check with local code authorities for minimum duct velocities. Do not use dampers in any kitchen application. NFPA 96.

Exhaust Ventilator, Hazardous Location, Centrifugal Sidewall Direct Drive, Wheel Dia. 11 In., CFM @ 0.000-In. SP 1180, Sones @ 0.250-In. SP @ 5 Ft. 13.0, Motor Voltage 115/208-230, 1 Phase, 60 Hz, Max. Operating Amps 4.0/2.0-2.0, Motor HP 1/4, Base Width 19 3/4 Dia In., Base Length 19 3/4 Dia In., Mounting Location Wall, Max. Inlet Temp 300 Deg F, Includes NEMA 7 & 9 Disconnect Switch, Mounted & Wired, Hazardous Location Motor That Meets Class I, Groups C & D and Class II, Groups F & G

More Products
Air King 9166 FanWhole House20 InAir KingFanWhole House20 In916646992(0 reviews)$312.10 + $27.30 Shipping
Air King 9018 Wall Mount Fan, 1970/1520/1170 cfm, 18 in.Air KingWall Mount Fan, 1970/1520/1170 cfm, 18 in.901849548(0 reviews)$97.60 + $13.00 Shipping
Air King 9016 Wall Mount Fan, 1510/1380/1190 cfm, 16 in.Air KingWall Mount Fan, 1510/1380/1190 cfm, 16 in.901646793(0 reviews)$77.60 + $13.65 Shipping
Air King 9145 Clip On Fan, 10-3/8 In. H, 8-1/8 In. LAir KingClip On Fan, 10-3/8 In. H, 8-1/8 In. L914548854(0 reviews)$27.35 + $8.45 Shipping
Lasko Products 2554 42" Wind Curve FanLasko Products42" Wind Curve Fan2554295324(0 reviews)$70.42 + $16.10 Shipping