Specs
| Item | Refrigeration Control |
|---|---|
| Type | Constant Cut In Control |
| Switch Type | SPST |
| Switch Action | Close on Rise |
| Control Range (F) | 18 to 27 |
| Normally Off (F) | 18 |
| Cold Off | 11.5 Degrees F |
| Warm Off | 26 |
| Capillary Length (In.) | 84 |
| Capillary Type | Capillary |
| Voltage | 120/240 |
| Locked Rotor Amps | 80 |
| Full Load Amps | 16/16 |
| Application | designed for applications requiring the defrosting of the evaporator coil during the time when the compressor is in the off cycle. The control is used in vending machines, automatic beverage dispensers, reach-in coolers and various other medium temperature commercial equipment. |
| For Use With | Vending Machines, Automatic Beverage Dispensers, Reach-In Coolers And Various Other Medium Temperature Commercial Equipment Requiring Off Cycle Defrost |
| Weight | 0.350000 |
| SKUs | 3XL05, RANA12-700 |
Description
Refrigeration ControlsNos. 3XL05 and 3XL06 provide off-cycle defrost. Generally used in systems without hot gas or electric defrost. 3XL11 terminates defrost and delays the evaporator fan operation on electric heat, hot gas, and reverse cycle commercial refrigeration systems.