Dayton 1A575

Dayton

Solenoid Valve, 2 Way, NC, 1/4 In, Brass

1A575 49889
Average Rating: n/a
 Be the first to write a review!
$35.89+ 3 Business Day Shipping $7.15

Sponsored Links

Specs

ItemSolenoid Valve
Number of Ways2
ConfigurationNormally Closed
Cv Flow Factor0.34
Pipe Size (In.)1/4
Orifice Dia. (In.)1/8
PSI Differential Min.0
Max. PSI Differential Air/Water150
Safe Working Water PSI500
GPM Max.4.2
Min. Flow Rate (GPM)3.4
Airflow (SCFM)28
Coefficient of Volume0.34
Max. Fluid Temp. (F)180
Coil Insulation ClassF
Coil EnclosureNEMA 1X
Body MaterialBrass
Gasket MaterialBuna N
Construction Reference No.1
Length1-1/2"
Width1-1/2"
Center Line Pipe Center Size (In.)5/16
Height2-7/8"
Agency ComplianceCSA, NFPA, UL
UNSPSC40141605
Weight 0.750000

Description

Solenoid Valve, Number of Ways 2, Configuration Normally Closed, Cv Flow Factor 0.34, 1/4 Pipe Size (In.), 1/8 Orifice Dia. (In.), PSI Differential Min. 0, Safe Working Water PSI 500, 28 Airflow (SCFM), 180 Max. Fluid Temp. (F), Coil Insulation Class F, Coil Enclosure NEMA 1X, Body Material Brass, Gasket Material Buna N, Construction Reference 1, Length 11/2 In., Width 11/2 In., Height 27/8 In.

Restrictions
  • WARNING: Not for use in explosive atmospheres. Note: Maximum suggested cycling rate is 10 times per min.
  • California Proposition 65 Warning: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm.

Solenoid Valves
  • To prevent backflow, add a check valve to the system (sold separately on page 4414). Valves that have OPD minimums beginning with 0 (e.g., 0 to 300 psi) are direct-acting and will open and close when line pressures are within minimum and maximum psi ranges. Valves that have OPD minimums starting at 2 or 5 (e.g., 5 to 150 psi) are designated pilot-operated and will open and close only if pressure differential between the inlet and outlet is within OPD ranges. Normally closed valves will open when energized. Normally open valves will close when energized.
  • Standards: UL; CSA; Fluid Control Institute, Inc.; National Fluid Power Association (NFPA).
  • Mount in any position

More Products
Honeywell TL8230A1003 T-Stat, Line V, Digital, 208-240 VHoneywellT-Stat, Line V, Digital, 208-240 VTL8230A1003 152274(0 reviews)$51.06 + $9.16 Shipping
Little Giant 577301 APCP-1700 1800 GPH Swimming Pool Cover PumpLittle Giant1800 GPH Swimming Pool Cover Pump577301 APCP-1700 113373(0 reviews)$217.90 + $14.95 ShippingOut of Stock
Cooper Atkins 24HP Food Srvc Thermometer, Oven, 100 to 600 FCooper AtkinsFood Srvc Thermometer, Oven, 100 to 600 F24HP 1314229(0 reviews)$12.05 + $7.15 Shipping
Econoline 526020G-40 Blast Media, 40 Lbs, Corn Cob, 14/20 GritEconolineBlast Media, 40 Lbs, Corn Cob, 14/20 Grit526020G-40 499763(0 reviews)$37.87 + $34.45 Shipping
UltraLube 10340 H1 Food Machinery Grease, 14 oz.UltraLubeH1 Food Machinery Grease, 14 oz.10340 1430567(0 reviews)$12.98 FREE Shipping